Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 31(22): 35971-35981, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-38017757

RESUMO

Optical equalization can be used for chromatic dispersion compensation in optical communication systems to improve the system performance; however, optical signal processing (OSP) is generally specifically designed for transmission channels, that is non-adaptive to dynamic transmission distortions compared with digital signal processing (DSP). In this contribution, we demonstrate optical equalization using a photonic integrated circuit (PIC) filter for chromatic dispersion compensation, with static and adaptive techniques: (a) the static optical equalizer is calibrated based on the known fiber dispersion and length, by using the fractional delay reference method; (b) the adaptive optical equalizer is updated iteratively to compensate transmission impairments based on a least-mean squares (LMS) algorithm. Experimental results show that both the static optical equalizer and the adaptive optical LMS equalizer can give an 18-dB Q-factor for a 14-Gbd QPSK signal transmitting over 30 km. To highlight the capability of the optical equalizers, we use simulations to show the improvement in dispersion compensating characteristics by implementing additional taps.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35533168

RESUMO

Brain-Machine Interfaces (BMI) offer the potential to modulate dysfunctional neurological networks by electrically stimulating the cerebral cortex via chronically-implanted microelectrodes. Wireless transmitters worn by BMI recipients must operate within electromagnetic emission and tissue heating limits, such as those prescribed by the IEEE and International Commission on Non-Ionizing Radiation Protection (ICNIRP), to ensure that radiofrequency emissions of BMI systems are safe. Here, we describe an approach to generating pre-compliance safety data by simulating the Specific Absorption Rate (SAR) and tissue heating of a multi-layered human head model containing a system of wireless, modular BMIs powered and controlled by an externally worn telemetry unit. We explore a number of system configurations such that our approach can be utilized for similar BMI systems, and our results provide a benchmark for the electromagnetic emissions of similar telemetry units. Our results show that the volume-averaged SAR per 10g of tissue exposed to our telemetry field complies with ICNIRP and IEEE reference levels, and that the maximum temperature increase in tissues was within permissible limits. These results were unaffected by the number of implants in the system model, and therefore we conclude that the electromagnetic emissions our BMI in any configuration are safe.


Assuntos
Interfaces Cérebro-Computador , Proteção Radiológica , Campos Eletromagnéticos/efeitos adversos , Humanos , Proteção Radiológica/métodos , Ondas de Rádio/efeitos adversos
3.
J Neural Eng ; 16(2): 026025, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30690434

RESUMO

OBJECTIVE: Implantable neural stimulating and recording devices have the potential to restore capabilities such as vision or motor control to disabled patients, improving quality of life. Implants with a large number of stimulating electrodes typically utilize implanted batteries and/or subcutaneous wiring to deal with their high-power consumption and high data throughput needed to address all electrodes with low latency. The use of batteries places severe limitations on the implant's size, usable duty cycle, device longevity while subcutaneous wiring increases the risk of infection and mechanical damage due to device movement. APPROACH: To overcome these limitations, we have designed and implemented a system that supports up to 473 implanted stimulating microelectrodes, all wirelessly powered and individually controlled by micropower application specific integrated circuits (ASICs). MAIN RESULTS: Each ASIC controls 43 electrodes and draws 3.18 mW of power when stimulating through 24 channels. We measured the linearity of the digital-to-analog convertors (DACs) to be 0.21 LSB (integrated non-linearity) and the variability in timing of stimulation pulses across ASICs to be 172 ns. SIGNIFICANCE: This work demonstrates the feasibility of a new low power ASIC designed to be implanted in the visual cortex of humans. The fully implantable device will greatly reduce the risks of infection and damage due to mechanical issues.


Assuntos
Eletrodos Implantados , Neuroestimuladores Implantáveis , Córtex Visual/fisiologia , Próteses Visuais , Tecnologia sem Fio/instrumentação , Humanos , Microeletrodos